Make sure that the S400 settings are correct and complete:
1) Go to the AMD Catalyst Pro software on the first system and set output 1 (i.e. Display computer 1/Display 1) and make it "Timing Server" 2) Check all other display outputs boxes as "timing clients"
3) Check RJ45 connections as "timing client" 4) Connect the second system with RJ45 cable to the "Timing Client" RJ45 output of the first system 5) On the second system select the connected RJ45 as "Timing Server" 6) Check all display outputs on the second system boxes as "Timing Clients" 7) In WATCHOUT, select the Display that will be syncmaster (i.e. Display computer 1/Display 1), open Display properties -> Advanced and check the box "Use as synchronisation chain master"
There is no purpose for the "House Sync (Genlocked)" unless the outputs need to be synced with video-sources. If so, do NOT connect the genlock signal to all S400 sync-cards, only to the selected "Timing Server" S400 card.
When the hardware side of things is setup, WATCHOUT should adhere to this.
注意: RJ45 cable要质量好的,短的,直接连接2张s400, 而不是连接到交换机/路由器。 同步卡并不是通过TCP/IP协议的.
|